Power
cableextension
Ifyouneedtoextendthelengthofthepowercablesuppliedwithyour
product,ensureyouobservethefollowingadvice:
•Thepowercableforeachunitinyoursystemshouldberunasaseparate,
singlelengthof2-wirecablefromtheunittothevessel'sbatteryor
distributionpanel.
•Ensurethattheextensioncableisofasufficientgaugeforthesupply
voltageandthetotalloadofthedeviceandthelengthofthecablerun.
Refertothefollowingtablefortypicalminimumpowercablewiregauges.
Cablelengthinmeters
(feet)
WiregaugeinAW G
(mm
2
)for12Vsupply
WiregaugeinAWG
(mm
2
)for24Vsupply
<8(<25)16(1.31mm
2
)18(0.82 mm
2
)
16(50)14(2.08mm
2
)18(0.82 mm
2
)
24(75)12(3.31mm
2
)16(1.31mm
2
)
>32(>100)10(5.26mm
2
)16(1.31mm
2
)
Important:
Beawarethatsomeproductsinyoursystem(suchassonarmodules)
cancreatevoltagepeaks atcertaintimes,whichmayimpactthevoltage
availabletootherproductsduringthepeaks.
Important:To ensurepowercables(includinganyextension)areofa
sufficientgauge,ensurethatthereisacontinuousminimumvoltageof
10.8Vdcattheendofthecablewhereitenterstheproduct’spower
connector,evenwithafullyflatbatteryat11Vdc.(Donotassumethata
flatbatteryisat0Vdc.Duetothedischargeprofileandinternalchemistry
ofbatteries,thecurrentdropsmuchfasterthanthevoltage.A“fullyflat”
batterystillshowsapositivevoltage,evenifitdoesn’thaveenoughcurrent
topoweryourdevice.)
Grounding
Ensurethatyouobserveanyadditionalgroundingadviceprovidedinthe
product’s documentation.
Moreinformation
Itisrecommendedthatbestpracticeisobservedinallvesselelectrical
installations,asdetailedinthefollowingstandards:
•BMEACodeofPracticeforElectricalandElectronicInstallationsinBoats
•NMEA0400InstallationStandard
•ABYCE-11AC&DCElectricalSystemsonBoats
•ABYCA-31BatterychargersandInverters
•ABYCTE-4LightningProtection
Warning:
Productgrounding
Beforeapplyingpowertothisproduct,ensureithasbeen
correctlygrounded,inaccordancewiththeinstructions
provided.
Warning:Positivegroundsystems
Donotconnectthisunittoasystemwhichhaspositive
grounding.
5.7Groundingconnection
TheY achtSense™Linkunitincludesadedicatedgroundingpoint,which
MUSTbeconnectedasdescribedbelow.
Important:
Connecttheproduct’sgroundingpointtoyourvessel’scommonRF
ground.OnvesselswithoutanRFgroundsystem,connecttheproduct’s
groundingpointdirectlytothevessel’snegativebatteryterminal.This
dedicatedgroundingpointisNOTanoptionalconnection.
Thevessel’sdcpowersystemshouldbeeither:
•Negativegrounded(“bonded”),withthenegativebatteryterminal
connectedtothevessel'sRFground.
•Floating,withneitherbatteryterminalconnectedtothevessel'sground.
Connections39