5.Waterproof
fuseholderwith8Afusemustbefitted
6.Positive(Red)wireconnectstopowersupplypositive(+)terminal.
In-linefuseandthermalbreakerratings
Thefollowingin-linefuseandthermalbreakerratingsapplytoyourproduct:
In-linefuseratingThermalbreaker rating
8A8A
Note:
Thesuitablefuseratingforthethermalbreaker isdependentonthe
numberofdevicesyouareconnecting.Ifindoubtconsultanauthorized
Raymarinedealer.
Y ourproduct’spowercablemayhaveanin-linefusefitted,ifnotthen
youmustaddanin-linefuse/breakertothepositivewireofyour
product’spowerconnection.
Caution:Powersupplyprotection
Wheninstallingthisproductensurethepowersourceis
adequatelyprotectedbymeansofasuitably-ratedfuseor
thermalcircuitbreaker.
Power distribution
Recommendationsandbestpractice.
Theproductissuppliedwithapowercable,eitherasaseparateitemora
captivecablepermanentlyattachedtotheproduct.Onlyusethepower
cablesuppliedwiththeproduct.DoNOTuseapowercabledesignedfor,
orsuppliedwith,adifferentproduct.
RefertothePowerconnectionsectionformoreinformationonhowto
identifythewiresinyourproduct’spowercable,andwheretoconnect
them.
Seebelowformoreinformationonimplementationforsomecommon
powerdistributionscenarios:
Important:
Whenplanningandwiring,tak
e
intoconsiderationotherproductsin
yoursystem,someofwhich(e.g.sonarmodules)mayplacelargepower
demandpeaksonthevessel’selectricalsystem,whichmayimpactthe
voltageavailabletootherproductsduringthepeaks.
Theinformationprovidedbelowisforguidanceonly,tohelpprotect
yourproduct.Itcoverscommonvesselpowerarrangements,butdoes
NOTcovereveryscenario.Ifyouareunsurehowtoprovidethecorrect
levelofprotection,pleaseconsultanauthorizeddealerorasuitably
qualifiedprofessionalmarineelectrician.
Implementationconnectiontodistributionpanel(Recommended)
1
Waterprooffuseholdercontainingasuitably-ratedinline
fusemustbefitted.Forsuitablefuserating,referto:In-line
fuseandthermalbreakerratings.
2
Productpowercable.
3
Drainwireconnectionpoint.
Itisrecommendedthatthesuppliedpowercableisconnectedtoasuitable
breakerorswitchonthevessel'sdistributionpanelorfactory-fittedpower
distributionpoint.
Thedistributionpointshouldbefedfromthevessel’sprimarypower
sourceby8AWG(8.36mm
2
)cable.
Ideally,allequipmentshouldbewiredtoindividualsuitably-ratedthermal
breakersorfuses,withappropriatecircuitprotection.Wherethisis
notpossibleandmorethan1itemofequipmentsharesabreaker,use
individualin-linefusesforeachpowercircuittoprovidethenecessary
protection.