wheel groove and contact tip.
4) No wire feeding, please confirm that the working mode is MIG state, please confirm that the welding gun is
connected well, press the gun switch or no wire feeding, please contact us.
5) During the welding process, if the time exceeds 3 minutes, over-current protection may occur. You need to stop
working for a few minutes, let the machine cool for a period of time, and automatically recover. If the air cools for
more than 10 minutes, the machine does not automatically recover, please shut down and restart.
6) If you have any questions, please contact us at.
B) Pulse gas shielded arc welding.
1 According to the aluminum welding wire material,select “Pulse/Al/Mg or Pulse/Al/Si
process.
2 Set polarity for MIG aluminum wiregas:
With gas protection, solid wire welding, connect "P" with "+" in the figure below.