9
SERVICE STG
Configure System >
Learning System >
Parameter >
Maintenance >
Functions >
SERVICE STG
Configure System >
Learning System >
Parameter >
Maintenance >
Functions >
Operation Mode >
Determines the functionality of sensors
and actuating devices during the close
cycle when the parameter MANUAL
CONTROL / DURING CLOSING is
enabled.
PARAMETER
Driving cycle >
Time delay open >
Drive >
Entrance system >
Manual control >
Control panel >
MANUAL CONTROL
During closing 0
When locked 0
Supp. dur. clos. 0
With active sens 0
Closing speed 10
MANUAL CONTROL
Closing speed 0
Opening assist 0
When auto 0
Obstruction 0
Supp. dur. clos. 0
Active sensors 0
ACTIVE SENSORS
0 disabled
1 OnDr Appr disabled
2 OnDr Appr enabled
SERVICE STG
Configure System >
Learning System >
Parameter >
Maintenance >
Functions >
SERVICE STG
Configure System >
Learning System >
Parameter >
Maintenance >
Functions >
Operation Mode >
This adjustment is functional only
when the Manual Control / During
Closing parameter has been enabled.
Otherwise, refer to the Closing Speed
adjustment on page 3.
PARAMETER
Driving cycle >
Time delay open >
Drive >
Entrance system >
Manual control >
Control panel >
MANUAL CONTROL
During closing 0
When locked 0
Supp. dur. clos. 0
With active sens 0
Closing speed 10
MANUAL CONTROL
When locked 0
When auto 0
Obstruction 0
Supp. dur. clos. 0
Active sensors 0
Closing speed 15
CLOSING SPEED
15
SERVICE STG
Configure System >
Learning System >
Parameter >
Maintenance >
Functions >
SERVICE STG
Configure System >
Learning System >
Parameter >
Maintenance >
Functions >
Operation Mode >
PARAMETER
Driving cycle >
Time delay open >
Drive >
Entrance system >
Manual control >
Control panel >
MANUAL CONTROL
When auto 1
Obstruction 1
Supp. dur. clos. 1
Active Sensors 2
Closing Speed 15
Opening Assist >
DRIVE
Opening angle 40
Obstruction Close 20
Brake 0
Types of arms 0
Inverse 0
Obstruction Opn 20
OPENING ASSIST
3 OnDr Appr enabled A
#3 OnDr Appr enabled A is sensor
active when door was opened
Automatically, not Manual.
0
When enabled, this setting provides an
assist to opening a heavy swing door.
As the door opens a few degrees, the
motor is actuated to assist the manual
opening of the door. After full open, will
time out and close normally.
SERVICE STG
Configure System >
Learning System >
Parameter >
Maintenance >
Functions >
SERVICE STG
Configure System >
Learning System >
Parameter >
Maintenance >
Functions >
Operation Mode >
PARAMETER
Driving cycle >
Time delay open >
Drive >
Entrance system >
Manual control >
Control panel >
MANUAL CONTROL
During closing 0
When locked 0
Supp. dur. clos. 0
With active sens 0
Closing speed 10
MANUAL CONTROL
Closing speed 0
Opening assist 0
When auto 0
Obstruction 0
Supp. dur. clos. 0
Active sensors 0
SUPP. DUR. CLOS.
0 disabled
1 Constant
2 Cumulative
3 Final bang
4 Slowly, cumulative
5 Slowly, final bang
With Manual Control / During Closing enabled
(above) -
0 disabled - provides no latch check
1 Constant - provides latch check & assist
2 Cumulative - no latch chk & ramped assist
3 Final bang - no latch chk & power hold
4 Slowly, cumulative - latch chk & ramped
5 Slowly, final bang - latch chk, no assist, and
power hold
SERVICE STG
Configure System >
Learning System >
Parameter >
Maintenance >
Functions >
SERVICE STG
Configure System >
Learning System >
Parameter >
Maintenance >
Functions >
Operation Mode >
PARAMETER
Driving cycle >
Time delay open >
Drive >
Entrance system >
Manual control >
Control panel >
CONTROL PANEL
Mechanical Panel 2
Display panel >
MECHANICAL PANEL
0 3 Pos. (AUTO)
1 4 Positions (VDAH)
2 3 Pos. (OFF-A)
8 3 Pos. (OFF-M)
9 3 Pos. (Lock-A)
10 3 Pos. (Lock-M)
3 Pos.(AUTO) is used on units when
no rocker switch is connected.
3 Pos.(OFF-M) is the normal setting.
3 Pos.(Lock-M) is used when a lock is
present and the door is to be locked
when turned OFF.
when power hold closed is desired.
3 Pos. (OFF-A) and (Lock-A) are used
4 Pos.(VDAH) is used with a BDE-M.
keyswitch or BDE-D Display module.