11-01
680 High Clearance Sprayer - Operation Instructions
Section B
Liquid Pumping & Plumbing
The liquid system begins with a suction line supplying a
pump. This pump is powered via tractor hydraulics, and
provides flow to the sprayer. The pump and plumbing
have been configured to provide for the following func-
tions:
• Fill Solution Tank
• Fill Solution tank, Utilizing Eductor (Optional)
• Fill Solution Tank, With Tank Agitation
• Fill Clean Water Rinse Tank
• Rinse Eductor While Filling (Optional)
• Rinse Agitation System
• Rinse Solution Tank
• Rinse Spray Boom Plumbing
• Spray
• Unload
Actual valve configuration will vary, depending on
options purchased.
Hydraulically Driven Centrifugal Pump (Optional)
Pump operation is very important. The following must be
followed when operating a hydraulically driven centrifugal
pump. Proper pump operation will make your system
operate with minimal maintenance and down time.
Failure to follow the manufacurer’s pump operation
instructions will void the pump warranty.
The pump must never be run in a non-flooded condition.
Operating the pump in a non-flooded condition will cause
extensive seal damage and possible pump damage. To
verify the pump is flooded, visually check pump vent line
for fluid, fluid will appear in vent line when pump is flood-
ed.
3
Section B
Hydraulically Driven
Centrifugal Pump
Under Tank View
Outlet
Suction Line
Vent Line
Boom Folded
Left Side View
Valve
Enclosure
Eductor System
(Optional)
Liquid Tank
Spray Boom
Cradle
Frame
Clean Water
Rinse Tank