OMP40-2 installation guide
1.4
Before you begin
Information to the equipment installer
All Renishaw equipment is designed to comply with the relevant EC and FCC regulatory requirements.
It is the responsibility of the equipment installer to ensure that the following guidelines are adhered to,
in order for the product to function in accordance with these regulations:
• any interface MUST be installed in a position away from any potential sources of electrical noise,
i.e. power transformers, servo drives etc;
• all 0 V/ground connections should be connected to the machine ‘star point’ (the ‘star point’ is a
single point return for all equipment ground and screen cables)
.
This is very important and failure to
adhere to this can cause a potential difference between grounds;
• all screens must be connected as outlined in the user instructions;
• cables must not be routed alongside high current sources, i.e. motor power supply cables etc, or be
near high speed data lines;
• cable lengths should always be kept to a minimum.
Equipment operation
If this equipment is used in a manner not specified by the manufacturer, the protection provided by the
equipment may be impaired.
Optical safety
This product contains LEDs that emit both visible and invisible light.
OMP40-2 is ranked Risk Group: Exempt (safe by design).
The product was evaluated and classified using the following standard:
BS EN 62471:2008 The photobiological safety of lamps and lamp systems.
Renishaw recommends that you do not stare at or look directly into any LED device, irrespective of its
risk classification.