2-211-001 On/Off E
[0 to 1 / 1 / 1/step]
0: Switch Off
1: Switch On with the reverse rotation sheet
counts for normal time
2212 [ExeSheets]
2-212-001 Normal E
[101 to 999 / 300 / 1page/step]
Cumulative sheets threshold after the last
reverse.
2-212-002 LowPrinting E
[1 to 500 / 50 / 1page/step]
This SP is not used and disabled. Changing
this SP does not affect the control.
Stops printing and executing reversing PCU
every sheets that has been set for low
printing.
2221
[LEDA Data:Display]
Displays LEDA data.
2-221-005 Serial No. E [- / - / -]
2-221-009 Power Error E [0 or 1 / 0 / 1/step]
2301
[T bias Control] Transfer Bias Control
Use these SP's to adjust the power output and power coefficient used to transfer the
toner image from drum to paper. Four separate voltages are applied before the
leading edge, at the leading edge of the paper, across the image area and at the
trailing edge of the paper.
Notes:
• The coefficient adjustment should be done before the power output.
• The amount of voltage applied to each area can be set independently in each
area for the type of paper in use.
2-301-002 T(+)_2_FaceOffset E
[-15 to 15 / 0 / 1uA/step]
Displays the setting of the offset amount of
transfer constant current level during creating
an image on the face page.
Main SP Tables-2
31