SC No.  Level  Error Name/Error Condition/Major Cause/Solution 
   
  ID sensor defective 
  ID sensor harness damaged. 
  ID sensor not connected correctly. 
  MPU defective 
  Laser unit defective 
  Imaging density fault 
  HVPS board defective 
  ID sensor dirt 
  Clean the ID sensor. 
  Replace the ID sensor. 
  Replace and reset the ID sensor harness. 
  Replace the MPU. 
  Replace the HVPS board. 
 
SC No.  Level  Error Name/Error Condition/Major Cause/Solution 
354-00  B  ID sensor: Auto adjustment timeout error (detailed) 
If Vsg is not automatically adjusted to 4.0±0.2 V twice 
consecutively when the ID sensor is adjusting Vsg automatically, 
this SC is issued (only when the SP5-995-001 is set to “1”). 
  ID sensor defective 
  ID sensor harness damaged. 
  ID sensor not connected correctly. 
  MPU defective 
  Laser unit defective 
  Imaging density fault 
  HVPS board defective 
  ID sensor dirt 
  Clean the ID sensor. 
  Replace the ID sensor. 
  Replace and reset the ID sensor harness. 
  Replace the MPU. 
  Replace the HVPS board.