SC Code Descriptions 
SM  6-32  D245/D246/D247 
6.2.6  SC6XX: DEVICE COMMUNICATION 
 
SC No.  Level  Error Name/Error Condition/Major Cause/Solution 
622-00  B  2nd tray communication error 
  An error occurs during the line connection between the 
mainframe and the optional PFU (2nd tray). 
  A communication error report is received between the 
mainframe and the optional PFU (2nd tray) is received. 
  The 2nd paper tray's main board defective 
  MPU defective 
  2nd tray and the machine are not connected correctly. 
  Reconnect the 2nd tray connection cable. 
  Replace MPU. 
  Replace the 2nd tray. 
 
SC No.  Level  Error Name/Error Condition/Major Cause/Solution 
623-00  B  3rd tray communication error 
  An error occurs during the line connection between the 
mainframe and the optional PFU (3rd tray). 
  A communication error report is received between the 
mainframe and the optional PFU (3rd tray). 
  2nd tray main board defective 
  3rd tray main board defective 
  2nd tray and 3rd tray not connected correctly 
  Reconnect the 2nd tray and 3rd tray connection cable. 
  Replace the 3rd tray.