Engine SP Mode 
 
SM  5-37  D245/D246/D247 
Maintenance 
5.2.7  SP7-XXX (DATA LOG 1) 
 
7001 
[Distance Counter]   
Displays the total operation distance. 
7-001-001
-  *ENG  [0 to 4294967295/ 0 / 1 mm / step] 
 
7621  [PM Count:Pages]   
Displays the page counter for each PM part. 
7-621-002
#PCDU  *ENG  [0 to 99999999/ 0 / 1 page / step] 
7-621-108
Paper Transfer Ro  *ENG  [0 to 99999999/ 0 / 1 page / step] 
7-621-115
Fusing Unit  *ENG  [0 to 99999999/ 0 / 1 page / step] 
 
7622  [PM Counter Reset]   
Clears the page counter for each PM part. 
7-622-002
#PCDU  ENG  [0 to 1/ 0 / 1 / step] 
7-622-108
Paper Transfer Ro  ENG  [0 to 1/ 0 / 1 / step] 
7-622-115
Fusing Unit  ENG  [0 to 1/ 0 / 1 / step] 
 
7623  [PM Set:Life Pages] 
7-623-002
Paper Transfer Ro  *ENG  DFU 
7-623-115