SC Code Descriptions 
SM  6-2  D245/D246/D247 
6.2  SC CODE DESCRIPTIONS 
6.2.1  SC1XX: SCANNING 
 
SC No.  Level  Error Name/Error Condition/Major Cause/Solution 
101-01  B  Lamp error (scanning) 
The white level peak did not reach the prescribed threshold 
when the white plate was scanned. 
   
  CIS defective 
  MPU defective 
  Harness defective 
  Condensation in the scanner unit 
  CIS dirty or positioned incorrectly 
  White plate dirty or positioned incorrectly 
1.  Perform the following operations. 
  Reconnect the harness of the CIS. 
  Reattach or clean the CIS. 
  Reattach or clean the white plate. 
2.  Replace the following parts. 
  Replace the CIS. 
  Replace the MPU. 
  Replace the harness of the CIS. 
 
SC No.  Level  Error Name/Error Condition/Major Cause/Solution 
102-00  B  LED light adjustment error 
The white peak exceeded the prescribed threshold when the 
white plate was scanned after a specified number of 
adjustments. 
  CIS defective. 
  MPU defective 
  Harness defective