To access the Advanced Menu press <MENU> button and then press the <Print> button 8 times. The
Advanced Menu will appear. Be sure to not have a print job loaded on the screen, as the Print will begin
once you press the print button.
Figure 9.3-13: Maintenance Station manual control Turn Pump On
Select Maintenance station and then select Pump On for Either CMYK or White. Now that the pump is on
use a syringe to put cleaning solution into each gasket on the maintenance station. It is only necessary to
put 5ml or half a syringe through each color channel. We recommend 10ml or one full syringe through
the white channels. If you notice any one channel drains slower it may be necessary to put more fluid
through this channel.
Figure 9.3-14: Pump OFF
When finished cleaning the Maintenance station, select Pump Off and secure the maintenance station.
Press <MENU> key to return to the Maintenance menu.