149
Figure 11.5-2 and Figure 11.5-3: Platform Startup Diagnose
Platform Diagnose
The Platform diagnose function prompts the operator to observe if the maintenance station has moved
up and down after the operator has moved up and down. If during diagnostic process the printer did not
detect the maintenance station platform position, two different errors depending on the operator’s
observance.
Figure 11.5-4: Platform Error Platform Moved
Figure 11.5-5: Platform Error Platform Did Not
Move
6: Home Table Time Out
If you receive a Home Table Timeout error, verify the grey CanBus cable is plugged to each of the boards
of the printer.
If all cables are connected and the Table motion Board (located on the back center floor of the printer)
does not receive power, the table will not move upon startup and thus results in a home table time out
error. Please contact a certified RICOH Ri 3000/Ri 6000 if this error occurs