Installation
6.11.2 Pump
The pump is designed to allow working with two pipes.
For the one pipe operation it is necessary to unscrew the return
plug 2) Fig. 18, remove the by-pass screw 3) and then the plug 2)
back in.
WARNING
Before starting the burner, make sure that the tank
return line is not clogged.
Obstructions in the line could cause the sealing
organ located on the pump shaft to break.
Fig. 18
D5405
380T1
394T1
397T1
5
4
2
3
6
9
7
10
8
1
398T1
S9657
Key to layout (Fig. 18)
1 Suction line
2 Return line
3 By-pass screw
4 Gauge connection
5 2nd stage pressure adjuster
6 Vacuum gauge connection
7 2nd stage valve
8 1st stage valve
9 Valve body unit
10 Auxiliary pressure test point
11 Pressure variator piston
12 1st stage pressure adjuster
WARNING
Check periodically the flexible pipes conditions.
If necessary, install a filter on the fuel supply line.