Example 3: Output a Ramp Waveform
How to generate a Ramp waveform with 10ms Period, 100mVPP Amplitude, 20mVDC
Offset, 80% Symmetry and 60° Phase.
The operation steps:
1. Set the Period.
(1) Press Ramp Freq/Period Period which will display in reverse color.
(2) Input “10” from the keypad and choose the unitms” to set the Period as 10ms.
2. Set the Amplitude.
(1) Press Ampl/ HiLev Ampl which will display in reverse color.
(2) Enter “100 from the keypad and choose the unit mVPP to set the Amplitude as
100mVPP.
3. Set the Offset.
(1) Press Offset /LoLev Offset which will display in reverse color.
(2) Enter 20” from the keypad and choose the unit mVDC to set the Offset as
20mVDC.
4. Set the Symmetry.
(1) Press Symm which will display in reverse color.
(2) Enter 80” from the keypad and choose the unit “%” to set the Symmetry as 80%.
5. Set the Phase.
(1) Press Phase which will display in reverse color.
(2) Enter “60” from the keypad and choose the unit °” to set the Phase as 60°.
After finishing the above settings, press View, the generated waveform is shown in
Figure 3-3.
Figure 3-3
Ramp Waveform Output