20 • Chapter 3: Operation GX-3R Operators Manual
4 . If BUMP.RMDR is set to ON (factory setting is OFF) and a bump test is due, the screen
that appears next depends on how BUMP.EXPD is set in User Mode (see
“BUMP.EXPD” on page 67). The three possible screens are described below. If a bump
test is not due, the instrument shows how many days are left until a bump test is due.
5 . The Date/Time Screen appears for a few seconds.
BUMP.EXPD set to
CONFIRM (factory setting)
BUMP.EXPD set to
CANT USE
BUMP.EXPD set to
NONE
LCD
Sound Buzzer sounds double pulsing
tone
Buzzer sounds double pulsing tone None
Action Option A, Perform bump test
:
Press and release POWER
MODE to perform a bump test.
The instrument takes you
straight to the BUMP CYL A
screen in User Mode’s BUMP
item. See “Performing a Bump
Test (BUMP)” on page 46 for
bump test instructions.
If the bump test is successful,
the screen above will not
appear again until the unit is
due for bump testing. If the
bump test is not successful, the
screen above will again appear
in the startup sequence.
Option B, Bypass message
: To
continue without performing a
bump test, press and release
AIR.
The GX-3R cannot be used until a
successful bump test has been per-
formed. Press and release POWER
MODE to perform a bump test.
The instrument takes you straight
to the BUMP CYL A screen in
User Mode’s BUMP item. If you
don’t press POWER MODE, the
instrument automatically goes to
the BUMP CYL A screen after 6
seconds. See “Performing a Bump
Test (BUMP)” on page 46 for
bump test instructions.
If the bump test is successful, the
screen above will not appear again
until the unit is due for bump test-
ing. If the bump test is not success-
ful, the screen above will again
appear in the startup sequence.
Option A, Perform bump test
:
To perform a bump test, press
and release POWER MODE.
The instrument takes you
straight to the BUMP CYL A
screen in User Mode’s BUMP
item.
Option B, Bypass message
: To
continue without performing a
bump test, wait a few seconds
for the instrument to continue
with its startup sequence.
BUMP--LMT
7:49
CAL
BUMP--LMT
7:49
FAIL
NEXT BP
7:49
0 d
7:49
7:49
18 - 12.22

Table of Contents

Related product manuals