21
The message "Not Available At The Moment" means that the xture is not connected to mains.
2. Enhanced pressure test - a special equipment Pressure IP Testing Set ROBE (P/N 10980659) is intended
for this kind of pressure test. Only trained technician should handle the equipment.
If this equipment is used for pressure test of the xture, the following values of pressure have to be kept:
Underpressure test.
300 mbar for 1 minute, pressure fall can be to 5 mbar maximally.
Overpressure test
150 mbar maximally!
5
. Operating the xture at ambient temperatures below 0°C
Design of the iForte/iForte FS allows its operation at ambient temperature up to -50°C, but you have to take
some specic into account before operating the xture.
1.Fixture is not in Standby mode.
iForte/iForte FS - ambient temperatures from 0°C to -10°C.
The xture can be switched o󰀨 but after powered it on, xture reset can be delayed in range of 0 - 30 minutes
depending on ambient temperature (max. delay is at low ambient temperature).This delay is caused by heating
xture e󰀨ects on operating temperature. The xture does not respond to DMX during heating the xture on
operating temperature.
We recommend to switch the xture on at least 30 minutes before show.
iForte/iForte FS - ambient temperatures from -11°C to -50°C.
The xture should be permanently powered on in order to keep operating temperature of xture´s e󰀨ects.
If the xture is switched o󰀨, reset of the xture will last long time (up to 1 hour depending on ambient
temperature) until xture e󰀨ects reach their operating temperature. The xture does not respond to DMX during
heating the xture on operating temperature.
2.Fixture is in Standby mode.
If the xture is switched to Standby mode (xture has to be connected to mains), the xture keeps internal
temperature on a level suitable for operation of xture´s e󰀨ects without delay, heating up of the xture inside
is done automatically.
Pressure IP Testing Set ROBE
in case: