The message "Not Available At The Moment" means that the xture is not connected to mains.
2. Enhanced pressure test - a special equipment Pressure IP Testing Set ROBE (P/N 10980659) is intended
for this kind of pressure test. Only trained technician should handle the equipment.
If this equipment is used for pressure test of the xture, the following values of pressure have to be kept:
Underpressure test.
300 mbar for 1 minute, pressure fall can be to 5 mbar maximally.
Overpressure test
150 mbar maximally!
5
. Operating the xture at ambient temperatures below 0°C
Design of the iForte/iForte FS allows its operation at ambient temperature up to -50°C, but you have to take
some specic into account before operating the xture.
1.Fixture is not in Standby mode.
iForte/iForte FS - ambient temperatures from 0°C to -10°C.
The xture can be switched o but after powered it on, xture reset can be delayed in range of 0 - 30 minutes
depending on ambient temperature (max. delay is at low ambient temperature).This delay is caused by heating
xture eects on operating temperature. The xture does not respond to DMX during heating the xture on
operating temperature.
We recommend to switch the xture on at least 30 minutes before show.
iForte/iForte FS - ambient temperatures from -11°C to -50°C.
The xture should be permanently powered on in order to keep operating temperature of xture´s eects.
If the xture is switched o, reset of the xture will last long time (up to 1 hour depending on ambient
temperature) until xture eects reach their operating temperature. The xture does not respond to DMX during
heating the xture on operating temperature.
2.Fixture is in Standby mode.
If the xture is switched to Standby mode (xture has to be connected to mains), the xture keeps internal
temperature on a level suitable for operation of xture´s eects without delay, heating up of the xture inside
is done automatically.
Pressure IP Testing Set ROBE
in case: