EasyManua.ls Logo

Robe iForte - Tab Service

Robe iForte
96 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
39
None - The option disables “Presetting playback” function.
Test - The option starts the test sequences.
Prog. 1 - The option starts user program No. 1.
Prog. 2 - The option starts user program No. 2.
Play program - Use the menu to run desired program in a loop.
Play Program 1 - The option starts user program No.1.
Play Program 2 - The option starts user program No. 2.
Edit Program - Use the menu to create or to edit desired program. The Robin iForte o󰀨ers 2 free programs,
each up to 80 steps.
Edit Program 1 - The option allows you to edit user program No.1.
Edit Program 2 - The option allows you to edit user program No.2.
To edit program:
1. Touch the item which you want to edit (“Edit Program 1” - “Edit Program 2”).
2. Touch the item "Edit Program Steps".
3. Touch the item "Step 1".
4 From the list of e󰀨ects touch desired e󰀨ect and set its value. Browse throw the list by touching the [up arrow]
and [down arrow] and set all desired e󰀨ects.
An item "Step Time" (value of 0-25.5 sec.) is the time during which e󰀨ects last in the current step
5. Save adjusted e󰀨ects to the current step by touching the [conrm] or save and copy them to the following
step by touching the [conrm+copy]. By touching the text box "Preview" next to the current program step you
can view created scene.
6. Repeat the steps 4 and 5 for next program steps.
7. After editing desired program steps, adjust the length of the program by touching the text boxes "Start Step"
and "End Step".
Meaning of the icons used in the "Edit Program" menu:
- moves down on the next page - saves adjusted values and leaves menu
- moves up on the previous page - saves values to the current step and copy them to the
following prog. step
- leaves menu without saving values
9.6 Tab "Service"
Pressure Test -
The menu item runs a procedure which checks the IP65 integrity of the xture.
The xture has to
be connected to mains and the head temperature (at pressure sensor) cannot be higher than 55°C. The pressure
test lasts about 10 minutes and can be run at earliest 8 minutes after closing light output (shutter closed) of the
xture. The pressure test can be repeated at earliest 2 minutes after last pressure test.
For more details of pressure test please see the chapter
Checking the IP65 integrity of the xture.
Adjust DMX Values - The menu allows you to set all e󰀨ects to desired positions before ne calibration of the
e󰀨ects .
Calibrations - This menu enables ne calibration of xture e󰀨ects and download default calibration values.
Calibrate E󰀨ects - The menu allows the ne adjustment of e󰀨ects.
Pan- a pan position ne adjustment (value range: 0-255)
Tilt - a tilt position ne adjustment (value range: 0-255)
E󰀨ect Wheel - an e󰀨ect wheel position ne adjustment (value range: 0-255)
Rot. Gobo Wheel 1 - a carousel 1 of rotating gobos ne movement (value range: 0-255)
R. Gobo Index 1/1 - a ne movement of the rotating gobo 1 (value range: 0-255)
R. Gobo Index 1/2 - a ne movement of the rotating gobo 2 (value range: 0-255)
R. Gobo Index 1/3 - a ne movement of the rotating gobo 3 (value range: 0-255)
R. Gobo Index 1/4 - a ne movement of the rotating gobo 4 (value range: 0-255)
R. Gobo Index 1/5 - a ne movement of the rotating gobo 5 (value range: 0-255)
R. Gobo Index 1/6 - a ne movement of the rotating gobo 6 (value range: 0-255)
Rot. Gobo Wheel 2 - a carousel 2 of rotating gobos ne movement (value range: 0-255)
R. Gobo Index 2/1 - a ne movement of the rotating gobo 1 (value range: 0-255)
R. Gobo Index 2/2 - a ne movement of the rotating gobo 2 (value range: 0-255)

Related product manuals