67
FAULT INFORMATION
ENG
Important
For these operations a precise technical expertise or ability is required; therefore, these operations must
be exclusively performed by qualified personnel with certified experience acquired in the specific field of
intervention.
No. of flashes
Problem
Cause
Solution
1 flash
Inverter communication
alarm
Electronic fault
Contact technical support
2 flashes
Plate alarm
Emergency plate pressed
Release the emergency plate and
reset the machine
3 flashes
Motor alarm
Inverter overload
Remove the overload cause.
Switch the machine off and then
on again
4 flashes
Table alarm
A fault or an obstacle is
preventing the table from moving
Remove the fault cause. Switch
the machine off and then on again
5 flashes
Film breakage alarm
Film breakage detected during a
wrapping cycle
Re-join the film to the product and
reset the machine) (Only available
with R-Connect with film
monitoring device)
6 flashes
Carriage alarm
A fault or an obstacle is
preventing the film carriage from
moving
Remove the fault cause. Switch
the machine off and then on again
7 flashes
Pallet start alarm
If the pallet is not present on the
machine, the machine will
remain stationary when the
CYCLE START button is
pressed
Position the product on the table
and start a new cycle