Rockwell Automation Publication 856T-UM001B-EN-P - April 2021 59
Appendix C Device Parameters
Open Circuit Status 0x014D/333 Read-only
00127
RecordT
(bit length = 8)
FALSE=0
Bit 0= Circuit 1 (TRUE/FALSE)
TRUE=1
FALSE=0
BOOL
(bit length = 1,
bit offset = 0)
FALSE=0
Bit 1= Circuit 2 (TRUE/FALSE)
TRUE=1
FALSE=0
BOOL
(bit length = 1,
bit offset = 1)
FALSE=0
Bit 2= Circuit 3 (TRUE/FALSE)
TRUE=1
FALSE=0
BOOL
(bit length = 1,
bit offset = 2)
FALSE=0
Bit 3= Circuit 4 (TRUE/FALSE)
TRUE=1
FALSE=0
BOOL
(bit length = 1,
bit offset = 3)
FALSE=0
Bit 4= Circuit 5 (TRUE/FALSE)
TRUE=1
FALSE=0
BOOL
(bit length = 1,
bit offset = 4)
FALSE=0
Bit 5= Circuit 6 (TRUE/FALSE)
TRUE=1
FALSE=0
BOOL
(bit length = 1,
bit offset = 5)
FALSE=0
Bit 6= Circuit 7 (TRUE/FALSE)
TRUE=1
FALSE=0
BOOL
(bit length = 1,
bit offset = 6)
Circuit Cycle Counter 0x0132/306 Read-only 0 0…4,294,967,296
RecordT
(bit length = 224)
Cycle counter (Circuit 1) 0x0132/306 0x0001/1 Read-only 0 0…4,294,967,296
UIntegerT
(bit length = 32,
bit offset = 192)
Cycle counter (Circuit 2) 0x0132/306 0x0002/2 Read-only 0 0…4,294,967,296
UIntegerT
(bit length = 32,
bit offset = 160)
Cycle counter (Circuit 3) 0x0132/306 0x0003/3 Read-only 0 0…4,294,967,296
UIntegerT
(bit length = 32,
bit offset = 128)
Cycle counter (Circuit 4) 0x0132/306 0x0004/4 Read-only 0 0…4,294,967,296
UIntegerT
(bit length = 32,
bit offset = 96)
Cycle counter (Circuit 5) 0x0132/306 0x0005/5 Read-only 0 0…4,294,967,296
UIntegerT
(bit length = 32,
bit offset = 64)
Cycle counter (Circuit 6) 0x0132/306 0x0006/6 Read-only 0 0…4,294,967,296
UIntegerT
(bit length = 32,
bit offset = 32)
Cycle counter (Circuit 7) 0x0132/306 0x0007/7 Read-only 0 0…4,294,967,296
UIntegerT
(bit length = 32,
bit offset = 0)
Cycle Counter -Life time 0X014B/331 0 Read-only 0 0…4,294,967,296
RecordT
(bit length = 224)
Cycle counter-Life time
(Circuit 1)
0X014B/331 0x0001/1 Read-only 0 0…4,294,967,296
UIntegerT
(bit length = 32,
bit offset = 192)
Cycle counter-Life time
(Circuit 2)
0X014B/331 0x0002/2 Read-only 0 0…4,294,967,296
UIntegerT
(bit length = 32,
bit offset = 160)
Cycle counter-Life time
(Circuit 3)
0X014B/331 0x0003/3 Read-only 0 0…4,294,967,296
UIntegerT
(bit length = 32,
bit offset = 128)
Cycle counter-Life time
(Circuit 4)
0X014B/331 0x0004/4 Read-only 0 0…4,294,967,296
UIntegerT
(bit length = 32,
bit offset = 96)
Cycle counter-Life time
(Circuit 5)
0X014B/331 0x0005/5 Read-only 0 0…4,294,967,296
UIntegerT
(bit length = 32,
bit offset = 64)
Table 14 - Observation Tab (Continued)
Parameter Name
Index
(Hex/Dec)
Sub Index
(Hex/Dec)
Access Default Value Allowed Value
Data Type