PowerFlex Digital DC Drive User Manual - Publication 20P-UM001C-EN-P - July 2008
Installation and Wiring 1-29
Figure 1.25 Frame C Control Circuit Terminal Block Location
Table 1.I Control Circuit Wire Sizes and Terminal Specifications
Figure 1.26 SA-SB Terminal Block Location on Frame B Drives
U2 V2
Frame
Drive Current Rating
Code
(1)
(1)
Refer to Catalog Number Explanation on page Preface-4, positions 8-10 for corresponding drive HP rating,
armature amp rating and field amp rating.
Terminals
Wire Size and Type
(2)
(2)
See Cable and Wiring Recommendations on page 1-14 for more information.
Tightening Torque
(N
m / lbsin)230V 460V
Flexible
(mm
2
)
Multi-core
(mm
2
)AWG
All All All U2, V2 0.14 - 1.5 0.14 - 2.5 26 - 14 0.5 / 4.4
Front of drive
The SA-SB
terminal block is
located at the top
of the drive.

Table of Contents