PowerFlex Digital DC Drive User Manual - Publication 20P-UM001C-EN-P - July 2008
3-58 Programming and Parameters
Communications File
File
Group
No.
Parameter Name & Description
See page 3-2 for symbol descriptions
Values
Related
COMMUNICATIONS
Comm Control
589 [DPI Baud Rate]
Shows the data transfer rate for attached drive peripherals.
“1” - 500 kbps
Default:
Min/Max:
Read Only
1 / 1
590 [DPI Port Sel]
Selects which DPI port reference value (unscaled) will
appear in Par 1343 [DPI Port Value].
Default:
Options:
1
1 =
2 =
3 =
4 =
5 =
“DPI Port 1”
“DPI Port 1”
“DPI Port 2”
“DPI Port 3”
“DPI Port 4”
“DPI Port 5”
1343
1321 [DPI Fdbk Select]
Selects the feedback variable and DPI units displayed on the
feedback line of the HIM.
0 “Speed” = Speed feedback units are in RPM
1 “Current” = Current feedback units are in %
Default:
Options:
0 =
0 =
1 =
“Speed”
“Speed”
“Current”
1343 [DPI Port Value]
Unscaled value of the DPI reference selected in Par 590 [DPI
Port Sel].
Default:
Min/Max:
Read Only
–/+32767
590
Masks & Owners
591 [Logic Mask]
Determines which ports can control the drive when Par 1377 [Write Mask Act], bit 15 is set to “1.” If the bit for a port is
set to “0,” the port will have no control functions except for stop. 0 = Control Masked, 1 = Control Permitted, x =
Reserved.
592 [Start Mask]
Controls which adapters can issue start commands.
See [Logic Mask]
593 [Jog Mask]
Controls which adapters can issue jog commands.
See [Logic Mask]
594 [Direction Mask]
Controls which adapters can issue forward/reverse direction
commands.
See [Logic Mask]
595 [Reference Mask]
Controls which adapters can select a manual reference.
See [Logic Mask]
596 [Accel Mask]
Controls which adapters can select the acceleration ramp
rates (Pars 660 [Accel Time 1] and 24 [Accel Time 2]) of the
drive.
See [Logic Mask]
24,
660
597 [Fault Clr Mask]
Controls which adapters can clear a fault.
See [Logic Mask]
598 [MOP Mask]
Controls which adapters can issue MOP commands to the
drive.
See [Logic Mask]
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
DPI Port 5
DPI Port 4
DPI Port 3
DPI Port 2
DPI Port 1
Digital In
Default
xxxxxxxxxx111111
Bit
1514131211109876543210

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation PowerFlex series and is the answer not in the manual?

Rockwell Automation PowerFlex series Specifications

General IconGeneral
BrandRockwell Automation
ModelPowerFlex series
CategoryDC Drives
LanguageEnglish