Events and Event Actions
22 AC-015 Hardware Installation and Programming Manual
8. Events and Event Actions
8.1 Tamper Event
A tamper event caused the AC-015 tamper output to open and alarm
sound generated (if enabled). A tamper event may occur due to
several reasons:
AC-015 cover is removed or broken.
A reader sensor wire is disconnected from the AC-015 reader
input terminal.
A tamper data signal is received from one of the reader sensors.
8.2 Clearing Tamper Events
To clear a tamper event, enter a valid employee or Lock Strike code
that opens the door locker output at that instance. For example,
during Secured status, entering Lock Strike Code 1 from the external
reader does not clear the tamper alarm because it is not permitted to
open the door at this status. However, applying the same code from
the internal reader does clear the tamper output.