12 x Technical data
ROTEX GCU compact -
57
12.1.2 GCU compact 5xx
Type (1)* GCU compact
Parameter Unit 515 / 515 BIV 524 / 524 BIV 533 / 533 BIV
Total storage capacity Litres 500
Empty weight (11)* kg 124
Total filled weight kg 624
Dimensions (L x B x H) cm 79 x 79 x 195
Maximum permissible storage water temperature °C 85
Stand-by heating power kWh/24h
1,8
Drinking water heat exchanger (stainless steel)
Water capacity heat exchanger Litres 24.5
Heat exchanger surface area m
2
5
Max. operating pressure for the potable water P
MW
(14)* bar 6
Storage tank charging heat exchanger (stainless steel)
Water capacity heat exchanger Litres 10.5 19,3
Heat exchanger surface area m
2
2.1 4.0
Pressurised solar heat exchanger (stainless steel)
Water capacity heat exchanger Litres — / 12.7 — / 12.7 — / 12.7
Heat exchanger surface area m
2
— / 1.7 — / 1.7 — / 1.7
Pipe connections
Cold and hot water Inch 1" AG
Heating feed and return flow Inch
1" IG
Thermal performance data (sanitary)
Efficiency characteristic N
L
according to DIN 4708
1)
2.1 2.2
D-value (specific Water flow) according to EN 625
2)
(15)* l/min 23 25 27
Continuous rating Q
D
according to DIN 4708 kW 15 24 33
Max. draw-off rate for a period of 10 min at
(TKW = 10°C / TSP = 60°C / TWW = 40°C)
Litres 20 23 24
Hot water quantity without reheating up to 15 l/min
tapping rate
(T
KW
= 10°C / T
WW
= 40°C / T
SP
=60°C)
Litres 230
Domestic hot water quantity with reheating at rated
output and 15 l/min at tapping rate
(T
KW
= 10°C / T
WW
= 40°C / T
SP
=60°C)
Litres 370 600 1300
Short time water quantity in 10 min
3)
Litres 200 230 240
Electrical system
Energy efficiency according to efficiency guidelines
Max. electric power consumption
(without/with heating circulation pump)
(9)* W 90
Max. electric power consumption in operating mode
"Standby"
W3,4
Voltage supply (8)* ~230 V, 50 Hz
Protection type (10)* IP X0B
1)
Reheating with nominal output, flow temp. T
V
= 80°C, starting storage tank temp. T
SP
= 65°C, cold water temp. T
KW
= 10°C, domestic hot
water temp. T
WW
= 45°C.
2)
The specific water flow according to EN 625 is the potable water flow with a mean temperature increase of 30 K, which the ROTEX GCU
compact is able to deliver in two consecutive tappings of 10 min duration each with a charging temperature of 65°C. A delay of 20 minutes
between the tw
o draw-off procedures is usually assumed. The ROTEX GCU compact reaches this value also with shorter waiting periods.
3)
Reheating with nominal output, starting storage tank temp. T
SP
= 60°C, cold water temp. T
KW
= 10°C, domestic hot water temp.
T
WW
= 40°C.
* Position numbers see fig. 12-1
Tab. 12-2 Technical data ROTEX GCU compact 5xx