Page 12 / 17 Saeco Internationa Group
05 SERVICE MODALITY TALEA / ODEA - LINE
Function group t.8 - Let steam out
Function group t.8 - Let steam out
Function group t.8 - Let steam out
t.8 -
steam out
next
boiler_temp (C°)
start
* *
t.8 -
steam out
next
boiler_temp (C°)
open knob to water & steam
start
* *
t.8 -
steam out
next
boiler_temp (C°) = 105.9
counter = 7.4
pass..
start
* *
boiler_temp (C°):
start:
*:
*:
current boiler temperature
Starts the steam out procedure
no function
no function
boiler_temp (C°):
open knob to w/st:
start:
*:
*:
current boiler temperature
Instruction to open hot water / steam
valve
Starts the steam out procedure
no function
no function
boiler_temp (C°):
counter:
pass:
start:
*:
*:
heats up to approx. 110 (C°)
counts from 10 to 0 (steam out time)
Steam out procedure completed
Starts the steam out procedure
no function
no function