VM1000 Series
‐104‐
Function
code
Description Set range Unit Default
Modifi
-cation
level
FC.02 Data bit check
0: No check (8, N, 2)
1: Even parity check (8, E, 1)
2: Odd parity check (8, O, 1)
3: No check (8, N, 1)
1 0
FC.03
Communication
response delay time
0ms~20ms 1ms 2
FC.04
Communication
timeout fault time
0.0 (invalid), 0.1~60.0s 0.1s 0
FC.05
Current resolution
of communication
0: 0.01A
1: 0.1A
1 0
FD Group:Multi-step Speed and Simple PLC Parameters
FD.00 Multi-step speed 0
-100.0%~100.0% (100.0% refers
to maximum frequency F0.10)
0.10% 0.00%
FD.01 Multi-step speed 1 -100.0%~100.0% 0.10% 0.00%
FD.02 Multi-step speed 2 -100.0%~100.0% 0.10% 0.00%
FD.03 Multi-step speed 3 -100.0%~100.0% 0.10% 0.00%
FD.04 Multi-step speed 4 -100.0%~100.0% 0.10% 0.00%
FD.05 Multi-step speed 5 -100.0%~100.0% 0.10% 0.00%
FD.06 Multi-step speed 6 -100.0%~100.0% 0.10% 0.00%
FD.07 Multi-step speed 7 -100.0%~100.0% 0.10% 0.00%
FD.08 Multi-step speed 8 -100.0%~100.0% 0.10% 0.00%
FD.09 Multi-step speed 9 -100.0%~100.0% 0.10% 0.00%
FD.10 Multi-step speed 10 -100.0%~100.0% 0.10% 0.00%