VM1000 Series
‐105‐
Function
code
Description Set range Unit Default
Modifi
-cation
level
FD.11 Multi-step speed 11 -100.0%~100.0% 0.10% 0.00% ☆
FD.12 Multi-step speed 12 -100.0%~100.0% 0.10% 0.00% ☆
FD.13 Multi-step speed 13 -100.0%~100.0% 0.10% 0.00% ☆
FD.14 Multi-step speed 14 -100.0%~100.0% 0.10% 0.00% ☆
FD.15 Multi-step speed 15 -100.0%~100.0% 0.10% 0.00% ☆
FD.16
Simple PLC
operation method
0:Stop after sigle operation
1:Keep the f inal value af ter single
operation
2:Operation in cycles
1 0 ☆
FD.17
Memory option of
simple PLC
Units:
0: Non-retentive at
power-off
1: Retentive at power-off
Tens:
0: Non-retentive at stop
1: Retentive at stop
11 0 ☆
FD.18
0th step running
time
0.0s(h)~6553.5s(h) 0.1s(h) 0.0s(h) ☆
FD.19
Acceleration time
of 0th step
0~3 1 0 ☆
FD.20
1st step running
time
0.0s(h)~6553.5s(h) 0.1s(h) 0.0s(h) ☆
FD.21
Acceleration time
of 1st step
0~3 1 0 ☆
FD.22
2nd step running
time
0.0s(h)~6553.5s(h) 0.1s(h) 0.0s(h) ☆