VM1000 Series
‐108‐
Function
code
Description Set range Unit Default
Modifi
-cation
level
FD.49
Acceleration time
of 15th step
0~3 1 0
FD.50
PLC operation time
unit
0: s
1: h
2: min
1 0
FD.51
Multi-step speed 0
frequency
reference
0: Function parameter FD.00
setting
1: AI1
2: AI2
3: Reserved
4: Pulse Input
5: PID
6: Digital setting of F0.08 Preset
Frequency(Adjustable Up/Down
keys)
1 0
FE Group: Parameter Management
FE.00 User Password 0~65535 1 0
FE.01
Fault Record times
display
0~15 1 5
FF Group: Reserved
E0 Group: Record of the last fault
E0.00
Code of the last
fault
0: No faults
1: Reserved
2: Overcurrent at
acceleration(Err02)
3: Overcurrent at
deceleration(Err03)
4: Overcurrent at constant
speed(Err04)