VM1000 Series
‐67‐
Function
code
Description Set range Unit Default
Modifi
-cation
level
F0.02
Base frequency for
UP/
DOWN
modification
during
running
0:Running Frequency
1:Preset Frequency
1 1 ★
F0.03
Master Frequency
Reference X
Selection
0:Digital setting of F0.08 Preset
Frequency(Adjustable by pulse
knob & Up/Down keys,
non-retentive at power off)
1:Digital setting of F0.08 Preset
Frequency(Adjustable by pulse
knob & Up/Down keys
modification, retentive at power
off)
2:AI1
3:AI2
4:Reserved
5:PULSE Input(DI6)
6:Multi-Step Speed Input
Frequency References
7:Simple PLC
8:PID
9:Communication
1 0 ★
F0.04
Auxiliary
Frequency
Reference Y
Selection
As the same as F0.03 1 0 ★
F0.05
Auxiliary
Frequency
Reference Y's
Range Reference
while in
superposition of X
and Y.
0:Refer to Maximium Frequency
1:Refer to Frequency Reference
X.