VM1000 Series
‐71‐
Function
code
Description Set range Unit Default
Modifi
-cation
level
F0.26
Resolution of
Frequency
Command
1:0.1Hz
2:0.01Hz
1 2 ★
F1 Group: Start and Stop Parameters
F1.00 Start Mode
0: Direct start
1: Rotator speed tracking and start
2: Asynchronous motor pre-excite
and start
1 0 ☆
F1.01
Rotator speed
tracking method
0: From the frequency at power off
1: From zero speed
2: From maximum frequency
1 0 ★
F1.02
Rotator tracking
speed
1~100 1 20 ☆
F1.03 Start frequency 0.00~10.00Hz 0.01Hz 0.00Hz ☆
F1.04
Holding time of
start frequency
0.0s~100.0s 0.1s 0.0s ★
F1.05
DC
braking/pre-excitin
g current before
start
0%~100% 1% 0% ★
F1.06
DC
braking/pre-excitin
g time before start
0.0s~100.0s 0.1s 0.0s ★
F1.07
Acceleration/Decel
eration mode
0: Linear
1: S-curve A
2: S-curve B
1 0 ★
F1.08
S-curve beginning
segment time ratio
0.0%~(100.0%.F1.09) 0.10% 30.00% ★