VM1000 Series
‐72‐
Function
code
Description Set range Unit Default
Modifi
-cation
level
F1.09
S-curve ending
segment time ratio
0.0%~(100.0%.F1.08) 0.10% 30.00% ★
F1.10 Stop mode
0: Decelerate to stop
1: Coast to stop
1 0 ☆
F1.11
Trigging frequency
of DC braking at
stop
0.00Hz~Maximum Frequency 0.01Hz 0.00Hz ☆
F1.12
Waiting time
before DC braking
at stop
0.0s~100.0s 0.1s 0.0s ☆
F1.13
DC braking current
at stop
0%~100% 1% 0% ☆
F1.14
DC braking time at
stop
0.0s~100.0s 0.1s 0.0s ☆
F1.15
Applying ratio of
braking unit
0%~100% 1% 100% ☆
F2 Group: Motor Parameters
F2.00 Drive model
0:General model (Constant torque
style‘s loads)
1:Pump model (Fan & Pump
style's loads)
1
Rated
Model
Dependent
●
F2.01 Motor rated power 0.1kW~400.0kW 0.1kW
Rated
Model
Dependent
★
F2.01
Motor rated
Voltage
1V~440V 1V
Rated
Model
Dependent
★