VM1000 Series
‐83‐
Function
code
Description Set range Unit Default
Modifi
-cation
level
F6.03
Relay 2 output
function
11: PLC cycle complete
12: Accumulative running time
reached
13: Frequency limited
14: Torque limited
15: Ready for Run
16: AI1>AI2
17: Frequency upper limit reached
18: Frequency lower limit reached
(no output at stop)
19: Undervoltage state output
20: Communication setting
21: Reserved
22: Reserved
23: Zero-speed running 2 (having
output at stop)
24: Accumulative power-on time
reached
25: Frequency level detection
FDT2 output
26: Frequency 1 reached
27: Frequency 2 reached
28: Current 1 reached
29: Current 2 reached
30: Timing reached
31: AI1 input limit exceeded
32: Load loss
33: Reverse running
34: Zero current state
35: Module temperature reached
36: Software current limit
exceeded
37: Frequency lower limit reached
(having output at stop)
38: Alarm output(Keep running)
39: Motor overheat warning
40: Current running time reached
41: User defined output 1
42: User defined output 2
1 1
F6.04
~F6.05
Reserved
F6.06
VDO output
function
1 0
F6.07~
F6.10
Reserved