EasyManua.ls Logo

SAJ VM1000 - F7 Group: Keypad & Display Interface Parameters

SAJ VM1000
148 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VM1000 Series
‐87‐
Function
code
Description Set range Unit Default
Modifi
-cation
level
F6.33
Test value selection
for user defined
output (EX) 2
0: Running frequency
1: Target frequency
2: DC bus voltage
3: Output voltage
4: Output current
5: Output Power
6: Output torque
7~8: Reserved
9: AI1 input value
10: AI2 input value
11: Reserved
12: Couter value
13: Length counting value
0
F6.34
Comparison
method of user
defined output 2
Units: comparison test method
0: Equal(EX==X3)
1: Equal or greater than
2: Equal or less than
3: Interval comparison(X3
EX X4)
4: Bits test(EX & X3 = X4
Tens: Output method
0: False value output
1: True value output
0
F6.35
User defined dead
interval 2
0 65535 0
F6.36
User defined output
2 comparison value
X3
0 65535 0
F6.37
User defined output
2 comparison value
X4
0 65535 0