VM1000 Series
‐88‐
Function
code
Description Set range Unit Default
Modifi
-cation
level
F7 Group: Keypad & Display Interface Parameters
F7.00
LCD yeypad
parameter copy
0: No operation
1: Local parameters will be copied
to LCD keypad
2: LCD keypad will download
parameters to local drive.
1 0 ●
F7.01 MF.K key function
0: No function
1: Switching control command
source between keypad and
remote control(Remote control
include communication and
terminals command).
2: Switching rotation between
FWD & REV
3: Jog Forward
4: Jog Reverse
1 0 ★
F7.02
STOP/RESET key
stop function
0: Only valid in keypad control
command mode
1: Always valid in any control
command mode
1 1 ☆
F7.03
Running status
LED display
selection 1
0000~FFFF
Bit00: Running frequency(Hz)
Bit01: Target frequency(Hz)
Bit02: DC bus voltage(V)
Bit03: Output voltage(V)
Bit04: Output current(A)
Bit05: Output Power(kW)
Bit06: Output torque(%)
Bit07: DI input status
Bit08: DO output status
Bit09: AI1 input value(V)
Bit10: AI2 input value(V)
Bit11: Reserved
Bit12: Counter value
1111 17 ☆