EB 8331-4 EN 25
Measures for preparation
3. Connect the power supply as described
in section5.2.
4. Retract actuator stem (3) as described in
section3.3.
5. Place actuator onto the valve bonnet
(2.3) and secure using the ring nut (7).
6. When the stem connector nut (8) rests on
the actuator stem, attach both stem con-
nector clamps (4) and fasten with screws.
Move actuator stem (3) to the end posi-
tion (valve closed) as described in sec-
tion3.3.
7. Align travel indicator scale (10) with the
middle of the stem connector (4) and
screw tight.
AttachmenttoType3214Valve(DN125to
250)
Î Refer to Fig.7
1. Connect the power supply as described
in section5.2.
2. Retract actuator stem (3) as described in
section3.3.
3. Place actuator onto the valve and secure
using the ring nut (7). If necessary, re-
tract the actuator stem slightly before-
hand.
4. When the plug stem ts closely onto the
actuator stem (3), attach both stem con-
nector clamps (4) and fasten with screws.
Move actuator stem (3) to the end posi-
tion (valve closed) as described in sec-
tion3.3.
5. Align travel indicator scale (10) with the
middle of the stem connector (4) and
screw tight.
Types3374-15/-26/-36
Connection with ring nut
Attachment to Series240 Valves
x
1
7
3
4
8
9
5
Fig.6: Attachment to Series240 Valves
Types3374-15/-26/-36
Connection with ring nut
Attachment to Type3214 Valve (DN125 to
250)
1
7
3
10
4
5
Fig.7: Attachment to Type3214