Operating Instructions and Installation
11-15Samsung Electronics
High Energy Efficiency brings benefits to you!
1. Unloaded Power Consumption is Only 10% of Full Load Power
The graph shows that the unloaded power consumption is 10% of full load power in case of 6 seconds loaded and 6 seconds
unloaded. In each cycle of modulation, the discharge pressure builds up during the loaded cycle, then the discharge pressure
decreases during the unloaded cycle. Similarly, the suction pressure decreases during the loaded cycle and it increases during
the unloaded cycle. The transition time to build up the pressure is a fraction of a second. The average value is around 0.4 sec-
ond.
2. Efficient Cooling and Heating System
Wide capacity ranges providing greater comfort room temperature
• Precise temperature control
• Quick response to room demands
• Low starting energy
• Efficient and reliable heating performance
Room temp
40°C
Room temp
20°C
Room temp
24°C
20Min 10Min
User comfort declines
Off OnOn
• Turn on the air conditioner
• Set temperature at 22°C
• Room is colder than desired.
• Start/Stops consumes energy.
• Room is warmer
than desired.
7,000
6,000
5,000
4,000
3,000
2,000
1,000
0
Power Consumption(W)
0 20 40 60 80 100 Time 0 20 40 60 80 100 Time
100% Loading
Loading 6,000W
Unloading 600W
Average Power Consumption(W)
P(100% Loading)=6,000W
P(75% Loading)=4,609W
P(50% Loading)=3,258W