6-20. Diagnosis for Sparkling system (Only for RF31FM*S*)
6. Self Diagnosis & Trouble Shooting
To do list
227
PROBLEM
Trouble
Shooting Step 1
Trouble Shooting
Step 2
Possible Causes SOLUTION
Nothing
coming
out when
pressing the
Sparkling
Water
Dispenser
Lever
Water coming out
when pressing
the Water
Dispenser Lever
When pressing the
Energy Saver button
(①) on the Display
Panel for 5 seconds
after opening the Fridge
Door, it will send off a
Ding Dong sound and
then the CO2 Valve will
be open for a second.
Confirm the Sound:
There are CO2 Valve
operating sounds.
But, there are no CO2
injection sounds.
-. Sounds occurring
when the CO2 Valve
is operating: "Tak"
-. Sounds occurring
when the CO2 is
being injected:
"Sui~k"
CO2 Run-out inside
the CO2 Cylinder
Replace the CO2
Cylinder
The CO2 Cylinder
Lever is not locked.
1. The CO2 Cylinder
Lever (⑪) is locked.
2. After opening the
Fridge Door, press the
Energy Saver button (①
)
on the Display Panel for
5 seconds and check if
CO2 is injected.