6-20. Diagnosis for Sparkling system (Only for RF31FM*S*)
6. Self Diagnosis & Trouble Shooting
To do list
227
PROBLEM
Trouble
Shooting Step 1
Trouble Shooting
Step 2
Possible Causes SOLUTION
Nothing
coming
out when
pressing the
Sparkling
Water
Dispenser
Lever
Water coming out
when pressing
the Water
Dispenser Lever
When pressing the
Energy Saver button
() on the Display
Panel for 5 seconds
after opening the Fridge
Door, it will send off a
Ding Dong sound and
then the CO2 Valve will
be open for a second.
Confirm the Sound:
There are CO2 Valve
operating sounds.
But, there are no CO2
injection sounds.
-. Sounds occurring
when the CO2 Valve
is operating: "Tak"
-. Sounds occurring
when the CO2 is
being injected:
"Sui~k"
CO2 Run-out inside
the CO2 Cylinder
Replace the CO2
Cylinder
The CO2 Cylinder
Lever is not locked.
1. The CO2 Cylinder
Lever () is locked.
2. After opening the
Fridge Door, press the
Energy Saver button (
)
on the Display Panel for
5 seconds and check if
CO2 is injected.