6-20. Diagnosis for Sparkling system (Only for RF31FM*S*)
6. Self Diagnosis & Trouble Shooting
To do list
228
PROBLEM
Trouble
Shooting Step 1
Trouble Shooting
Step 2
Possible Causes SOLUTION
Nothing
coming
out when
pressing the
Sparkling
Water
Dispenser
Lever
Water coming out
when pressing
the Water
Dispenser Lever
When pressing the
Energy Saver button
() on the Display
Panel for 5 seconds
after opening the Fridge
Door, it will send off a
Ding Dong sound and
then the CO2 Valve will
be open for a second.
Confirm the Sound:
There are no CO2
Valve operating
sounds.
-. Sounds occurring
when the CO2 Valve
is operating: "Tak"
-. Sounds occurring
when the CO2 is
being injected:
"Sui~k"
Defective CO2
Injection Valve
1. Reset the CO2
Cylinder by pressing the
Sparkling Water button
() for 3 seconds
on the Display Panel and
reproduce the Sparkling
Water.
2. When there is no
CO2 injection even after
completing the
reproduction
of the Sparkling Water,
replace the Module.