EasyManuals Logo

Sanyo PLC-HP7000L Specifications

Sanyo PLC-HP7000L
27 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
PLC-HP7000L Basic Serial Command Functional Specifications
27/27
7.8 Temp Read Command
Command
CR6” [CR]
Detail
Get the information of temperature inside a projector.
With several built-in temperature sensors, it can get all the temperatures at once.
Acceptable “%1 _ %2 _ %3” [CR]
%1
%2
%3
%1 = Temp. of sensor 1
%2 = Temp. of sensor 2
%3 = Temp. of sensor 3
Temperature data basic format is “_00.0”. (“_” indicates a space)
When the temperature goes under 0, it starts with “-” instead of a
space like “-05.5” [CR].
When no temperature data returns due to hardware problems, it
starts with “E” like”E00.0” [CR].
With several built-in temperature sensors, the projector returns
the values in succession.
“_31.5_ _35.2_ 33.4 ” [CR]
The first sensor’s data is followed by one space and afterwards
the second sensor’s data.
Response
Unacceptable
“?” [CR]
7.9 Lamp Mode Read Command
Command
CR7” [CR]
Detail
Get lamp mode.
In the projector with single lamp, get ON/OFF status of the lamp
Acceptable “%1” [CR]
%1
“00” [CR] = Lamp is ON.
“01” [CR] = Lamp is OFF.
Response
Unacceptable
“?” [CR]

Table of Contents

Other manuals for Sanyo PLC-HP7000L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sanyo PLC-HP7000L and is the answer not in the manual?

Sanyo PLC-HP7000L Specifications

General IconGeneral
Brightness7000 ANSI Lumens
Contrast Ratio2000:1
Lamp Life2000 hours (Normal Mode), 3000 hours (Eco Mode)
Lamp TypeUHP
Projection Size30 - 300 inches
Resolution1024 x 768 (XGA)
Projection MethodFront, Rear, Ceiling
Input ConnectorsHDMI, VGA, Composite Video