-48-
Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
1 Y-OFFSET AREA V START
Y - Offset Acquiring Area V-Start
Position
500 0 - 1000
2
CB - OFFSET AREA H
START
CB - Offset Acquiring Area H-Start
Position
925 0 - 1000
3
CB - OFFSET AREA V
START
CB - Offset Acquiring Area V-Start
Position
500 0 - 1000
4
CR - OFFSET AREA H
START
CR - Offset Acquiring Area H-Start
Position
925 0 - 1000
5
CR - OFFSET AREA V
START
CR - Offset Acquiring Area V-Start
Position
500 0 - 1000
6 Y - GAIN AREA H START 50 0 - 1000
7 Y - GAIN AREA V START 500 0 - 1000
8 CB - GAIN AREA H START 800 0 - 1000
9 CB - GAIN AREA V START 500 0 - 1000
10 CR - GAIN AREA H START 700 0 - 1000
11 CR - GAIN AREA V START 500 0 - 1000
12 Image AREA H WIDTH YCBCR Level Acquiring Area 13 0 - 4095
13 Image AREA V HIGHT YCBCR Level Acquiring Area Height 9 0 - 4095
14 Y - OFFSET TARTGET 4 1 - 255
15 CB OFFSET TARGET 128 1 - 255
16 CR OFFSET TARGET 128 1 - 255
17 Y-GAIN TARGET 217 1 - 255
18 CB-GAINTARGET 237 1 - 255
19 CR-GAINTARGET 237 1 - 255
20 OFFSET torelance Torelance of OFFSET Adj. 1 1 - 255
21 GAIN torelance Torelance of GAIN Adj. 1 1 - 255
Group
270
CUSTOM(Aspect)
0 Scaler Horizontal Horizontal Scaler Edit 100 68-132
1 Sclaler Vertical Vertical Scaler Edit 100 68-132
2 Connect Seperate/Connect Edit 0 0-1 0:Seperate, 1: Connect
3 Position Horizontal Horizontal Postion Correction 100 85-115
4 Position Vertical Vertical Position Correct 100 85-115
5 Aspect Enable 0 0 - 1 0: False, 1: True
Group
280
AutoPC Adjust
0 AutoPCAdjustEnable
Auto-PC Adj Operation Enable if Un-
supported Signal Input
0 0-1 0:Enabel, 1:Disable
1 Frequency Step Frequency Steps of Total Dot 1 0-3
2 Frequency Threshold Total Dot Freqency Threshold 5 0-10 0[]<-- - --> 10[Not matched]
3 Fine Phase Do Phase Adj after Total Dot Adj. 1 0-1 0;Excutes Fine Phase; 1:Not Excute
4 BLKDET Black Level Detection Area 1 0 - 7
5 PHASEMSK Phase Detection Filter 0 0 - 3
0: Effective All Bit,
1: Disable Lower 1 bit
2: Disable Lower 2 bit, 3: Disable
Lower 3 bit
Group
290
PanelType * Not used for this model
0 GammaL/R-View Current Setting Check 0 0-20
0: Gamma for L-Turn
20: Gamma for R-Turn * Read only
1 GammaL/R-Change Setting of Gamma 10 0-20
Sets L-Turn Gamma if the Value is
set to 0.
Sets R-Turn Gamma if the Value is
set to 20.
Group
500
Composite (NTSC) Composite / S-Video
1 Disp Dots 668 0 ~ 4095
2 H Back Porch 28 0 ~ 4095
3 V Back Porch 18 0 ~ 4095
4 Disp Line 458 0 ~ 4095
Group
501
Composite (PAL) Composite / S-Video
1 Disp Dots 658 0 ~ 4095
2 H Back Porch 34 0 ~ 4095
3 V Back Porch 22 0 ~ 4095
4 Disp Line 536 0 ~ 4095
Group
502
Composite (SECAM) Composite / S-Video
1 Disp Dots 652 0 ~ 4095
2 H Back Porch 28 0 ~ 4095
3 V Back Porch 22 0 ~ 4095