PR 5210 Operating Manual Appendix
Sartorius 75
8.3 Spare parts
Order number Description Beschreibung
5312 264 48012 Connector 4-pol. Stecker 4-pol.
5312 321 28046 PC-connection cable 2m PC-Anschlusskabel 2m
5312 447 98005 Blind cap Blindkappe
8.4 Example print out configuration and calibration data /
parameters
Configuration / Calibration Data
Data set for device: PR 5210/00 - Rel.3.00
Serialnr: 4294967294 06.10.2004 11:55:03
FSD 3000 kg
Stepwidth 1
Deadload 0,000000 mV/V
Span 1,000000 mV/V
Overload 9 d
Filter none
Frequency 1,56 Hz
Measuring time 320 msec
Weight & Measure off
Standstill time 1 M
Standstill range 1,00 d
Testmode absolute
Standstilltimeout 8 M
Zeroset range 50,00 d
Zerotrack range 0,25 d
Zerotrack step 0,25 d
Zerotrack repeat 0 M
Analog mode off
Analog range 4...20 mA
Analog error 0 mA
Analog < 0 linear
Analog > FSD 20 mA
Analog value 0,000 mA
Weight 0/4 mA 0 kg
Weight 20 mA 3000 kg
Profibus address 10
Bus size 8
Remote display on
Baudrate 9600
Access 0
Output 1 transparent
Output 2 transparent
Output 3 transparent
Input 1 none
Input 2 none
Input 3 none
Limit 1 on 0 kg
Limit 1 off 0 kg
Limit 2 on 0 kg
Limit 2 off 0 kg
Limit 3 on 0 kg
Limit 3 off 0 kg
Value for 4 mA 4,000
Value for 20 mA 20,000

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sartorius PR 5210 Series and is the answer not in the manual?

Sartorius PR 5210 Series Specifications

General IconGeneral
BrandSartorius
ModelPR 5210 Series
CategoryTransmitter
LanguageEnglish

Related product manuals