machine or if the product being sorted contains a high percentage of defects, the
regulator should be set to 45 psi while the machine is operating.
1.3.6 DUST EXTRACTION
Two 4 inch outside diameter dust removal outlets are provided on the rear side of
the ScanMasterII just above the lower power supply enclosure (See Figure 1-3).
These outlets should be connected to an exhaust system to remove dust from the
viewing area. An air flow rate of 530 cubic feet per minute is recommended.
This will reduce the amount of manual cleaning required and provide more
consistent and efficient operation of the machine.
1.3.7 OTHER CONSIDERATIONS AND PRECAUTIONS
DO NOT WELD DIRECTLY TO THE MACHINE. Further, when welding or painting
around the machine, be sure to cover it. Special attention should be paid to avoid
cuttings, welding splatter or paint on the chutes.
Any hopper installed above the input hopper on the machine must not touch the
machine. If the hopper does touch the machine, it can transfer vibrations to the
machine that will cause the product to flow through the feeders, even if the feeders
are turned off. The vibration can also have other adverse effects.
A product cut-off gate must be installed between the plant input hopper above the
machine and the machine input hopper. This will permit the machine hopper to be
emptied for service if required.
Take-away chutes or conveyors also should not be directly connected to the
machine.
The take-away system should have provisions to take samples of both accepts from
each individual chute and rejects from each machine. This will enable the operator
to determine each machine’s performance and adjust it for highest efficiency and
best reject concentration.

Table of Contents