12
4.7 Extended Instrument Status
Table 4-11 Read Request
Message type (ASCII)
?
Message body (hexadecimal)
Request - no body
Response
Field Offset Length Parameter Range
1 0 4 Relay status see Table 4-12
2 4 4 Not used 0
3 8 4 Not used 0
4 12 4 Setpoints status see Table 4-13
5 16 4 Log status see Table 4-14
6 20 36 Not used 0
Table 4-12 Relay Status
Bit Description
0 Relay status
1-15 Not used (permanently set to 0)
Bit meaning: 0 = relay released, 1 = relay operated
Table 4-13 Setpoints Status
Bit Description
0 Setpoint # 1 status
1 Setpoint # 2 status
2 Setpoint # 3 status
3 Setpoint # 4 status
4 Setpoint # 5 status
5 Setpoint # 6 status
6 Setpoint # 7 status
7 Setpoint # 8 status
8 Setpoint # 9 status
9 Setpoint # 10 status
10 Setpoint # 11 status
11 Setpoint # 12 status
12 Setpoint # 13 status
13 Setpoint # 14 status
14 Setpoint # 15 status
15 Setpoint # 16 status
Bit meaning: 0 = setpoint is released, 1 = setpoint is operated
Table 4-14 Log Status
Bit Description
0 Reserved
1 New Min/Max log
2-15 Not used (permanently set to 0)
Bit meaning: 0 = no new logs, 1 = new log recorded (the new log flag is reset when the user reads the first
log record after the flag has been set)