EasyManua.ls Logo

SATO CL408 - Custom Protocol Command Codes

SATO CL408
249 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Custom Protocol Command Codes
Download
Command Structure <ESC>LD,a,b,c,d,e,f,g,h,i
a = Replacement character for STX in ASCII or hex format
b = Replacement character for ETX in ASCII or hex format
c = Replacement character for ESC in ASCII or hex format
d = Replacement character for ENQ in ASCII or hex format
e = Replacement character for CAN in ASCII or hex format
f = Replacement character for NULL in ASCII or hex format
g = Replacement character for OFFLINE in ASCII or hex format
h = Auto-Online. Printer powers up in the On Line mode.
0 = Yes
1 = No
i = Zero Slash. Places a slash through the “0” character.
0 = Yes
1 = No
Example: <ESC>LD,{,},%,#,&,*,~,0,0
Placement: Immediately following the <ESC>A Start command and in
an independent data stream.
Default: Standard Protocol command Codes
Command Function Allows the user to defines custom Protocol Command codes.
Printer Input
<ESC>A
<ESC>LD,{,},%,#,&,*,~,0,0
<ESC>Z
Printer Output A Protocol Command code status label will be printed as a result of
the a successful download of a custom set of Protocol Command
codes.
STX = 7B ETX = 7D ESC = 25
ENQ = 23 CAN = 26 NULL = 2A
OFFLINE = 7E
AUTO ONLINE = YES
ZERO SLASH = YES
Press the “FEED” key to activate the User
Default or power the printer off to ignore
them.
Section 4. Programming Reference