Page 3-12
Section 3. Interface Specifications
SATO CL408e/CL412e Service Manual
PN 9001078
Rev. A
NOTE: The signals on pins 1, 3, 4, 6, 9 and 10 each have an open collector output. These pins normally
measure +.07V maximum when a true condition exists. If a false condition occurs, the voltage will drop to
0V. To achieve a signal level of +5V, you must add a 330 ohm, ¼ W pull-up resistor between the open
collector output pin and Vcc (pin 13) as illustrated. This will provide a signal level of +5V for a true
condition and 0V when a false condition exists. The maximum voltage that can be applied to these pins is
+50V and the maximum current they can sink is 500 milliamps.
Pin 13
Vcc= +5V
330 ohm, 1/4W
Pin 1, 3, 4, 6, 9 or 10
Signal Out
Standard Operation
Start of Print Cycle End of Print Cycle
Print Start
Input
+5V
0V
Print Repeat
Input
+5V
0V
+5V
0V
+5V
0V
Print End
Type 1
Print End
Type 2
+5V
0V
Print End
Type 3
Print End
Type 4
+5V
0V
20 Milliseconds