Page 4-16
Section 4. Electric Checks and Adjustments
SATO CL408e/CL412e Service Manual
PN 9001078
Rev. A
4.10 Print Darkness Adjustment
1. Open the Front Door for access to Pitch Potentiometer.
2. Turn the power switch ON.
3. Send print data from your PC and confirm the result.
4. Adjust the Pitch Potentiometer to obtain optimum print quality. If
quality is still lacking, refer to Section 2 Configuration, Print Darkness
Setting, page 2-9.
ADJUST PITCH
POTENTIOMETER
FOR OPTIMUM
PRINT
STEP PROCEDURE