EasyManua.ls Logo

SATO CL408e - Real Time Clock Installation

SATO CL408e
219 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 9-26
Section 9. Optional Accessories
SATO CL408e/CL412e Service Manual
PN 9001078
Rev. A
The Real Time Clock Chip allows the date and time to be maintained in the local
printer rather than using the system clock. It consists of a special clock chip that
replaces the EEPROM chip on the main PCB.
9.6 Real Time Clock Installation
RAISE THE TOP ACCESS
DOOR AND REMOVE (2)
SCREWS HOLDING THE SIDE
COVER TO THE FRAME
REMOVE (2) SCREWS
HOLDING THE SIDE COVER
TO THE OUTSIDE FRAME
STEP PROCEDURE
1. Turn the printer OFF and disconnect the AC power cord.
2. Raise the access door and remove (2) screws holding the left side
cover to the inside frame. Figs. 9-41
3. Remove (2) screws holding the left side cover to the outside frame.
Remove the cover to expose the main PCB.
ELECTRONICS
COMPARTMENT
REMOVE LEFT
SIDE COVER
Figs. 9-41