10 Commands And Functions
118
innovators for industry
List Command set_wait
Function sets a wait marker (break point) in the list
Parameter
wait_word
number of the wait marker as an unsigned 16-bit value [1 65535]
Integration Pascal:
function set_wait(wait_word: word);
C:
void set_wait(unsigned short wait_word);
Basic:
sub set_wait(ByVal wait_word%)
Comments Processing of a list will be interrupted at each wait marker.
The laser will be turned off.
If processing has been stopped at a wait marker, the command get_wait_status
returns the number of this marker.
Processing of the list can be resumed by calling the command release_wait.
References get_wait_status, release_wait
List Command set_wobbel
Function defines a circular movement of the output position which is added to the regular
marking movement
Parameters
amplitude
amplitude of the circular wobbel movement in bits (unsigned 16-bit value)
Allowed range: [1 5000]
frequency
frequency of the wobbel movement in Hz
(circles per second, 64-bit IEEE floating point value)
Allowed range: [1 6000]
Integration Pascal:
procedure set_wobbel(amplitude: word; frequency: double);
C:
void set_wobbel(unsigned short amplitude, double frequency);
Basic:
sub set_wobbel(ByVal amplitude%, ByVal frequency#)
Comments Calling the command set_wobbel sets the wobbel phase to a defined starting value
(which is independent of the direction of the marking vector).
The wobbel function can be used for marking lines with variable line width.
A circular movement is added to the linear marking movement, resulting in a spiral
movement of the laser focus in the image field.
A broad line is obtained by choosing suitable values for the amplitude and the
frequency. The amplitude and the frequency must be appropriate for the current
marking speed.
The wobbel function is terminated by setting the amplitude to zero.
References set_mark_speed