RTC
®
4 PC Interface Board
Rev. 1.3 e
10 Commands And Functions
75
innovators for industry
Ctrl Command auto_change
Function activates an automatic list change
Integration Pascal:
procedure auto_change;
C:
void auto_change(void);
Basic:
sub auto_change()
Comments The auto_change command should only be used when working with two lists (up to
4000 commands each). This command should only be used if a list is currently
executing, or if it has already executed. Additionally, the other list should have already
been loaded and closed.
With automatic list changing activated, the next list will start automatically after the
current list is finished.
For each subsequent list, use a separate auto_change call.
The current status of both lists can be read with the commands
get_status (page 86) or read_status (page 100).
See "Automatic List Handling", page 13.
References get_status, read_status
Ctrl Command auto_change_pos
Function activates an automatic list change
Parameter
start
Start position (address) of the next command sequence to be executed
(unsigned 16-bit value)
allowed range: [0 7999]
Integration Pascal:
procedure auto_change_pos(start: word);
C:
void auto_change_pos(unsigned short start);
Basic:
sub auto_change_pos(ByVal start%)
Comments Use the auto_change_pos command when the RTC
®
4’s entire memory is treated like
a single list buffer.
With automatic list changing activated, finishing of a list will automatically result in
continuation of execution at the specified start position.
The current status of a list can be read with the commands
get_status (page 86) or read_status (page 100).
See "Automatic List Handling", page 13.
References get_status, read_status