Schaeer Technologies
13
■ Remove the packaging and place the induction heater on
a non-ferrous, stable and level surface. Put heaters with
wheels on the brake to prevent the heaters from moving.
■ A Schaeer heater is supplied with ledges, 2 temperature
sensors, heat-resistant gloves (suitable up to 250°C /
482°F) and acid-free grease.
■ Check the connection voltage against the rating plate on
the unit.
■ Each heater is equipped with a plug. As there is a wide
variety of plug types, the attached plug may not fit. In such
cases, obtain a proper plug. It must be fitted by a qualified
electrician.
■ There are dierent fitting options depending on the type of
cable on the heater:
Fitting options HEATER50 - 200 SMART
120V/230V 1 phase heaters
Brown Phase
Blue Zero
Green/Yellow Ground
120V/240V 1 phase heaters
Black Phase
White Zero
Green Ground
400V/450V/500V 2 phase heaters
Brown Phase
Blue or
Black
Zero
Green/Yellow Ground
4. Installation